Anemometer
|
Vane LV 100
|
|
LV 101 - LV 107 - LV 110
Functions :Vane velocyti and airflow, temperature.
Technical data
- LV 101 - Ø 14 mm vane
- Air velocity : 0,8 to 25 m/s
- Temperature : -20 to +80°C
- Air flow : 0 to 99999 m³/h
- LV 107- Ø 70 mm vane
- Air velocity : 0,3 to 35 m/s
- Temperature : -20 to80°C
- LV 110- Ø 110 mm vane
- Air velocity : 0,25 to 35 m/s
- Air flow : 0 to 99999 m³/h
- Temperature : -20 to +80°C
Supplied with vane, transport case and calibration certificate.
|
|
Vane LV 130
|
|
Vane probe thermo-anemometer
Ø 100 mm vane probe.
Functions air velocity, airflow, ambient temperature.
- 2 models
- LV 130 : rotating vane probe
- LV 120 : fixed vane probe
- LV 107- Ø 70 mm vane
- Air velocity : from 0.25 to 35 m/s
- Airflow : from 0 to 99.999 m3/h
- Temperature : from 0 to +50°C
Supplied with transport case and calibration certificate.
|
|
Vane VT 200
|
|
Anemometer
Functions: Velocity, airflow, temperature.
8, 000 measuring points
DATALOGGER software (option)
- Anemometer
- Ø 70 mm vane : from 0,3 to 35 m/s
- Ø 100 mm : from 0,25 to 35 m/s
- hotwire : from 0,15 to 30 m/s
- Temperature
- Temperature Pt100 :
- -20 to +80°C (in hotwire or vane probes)
- -50 to +250°C (according to model)
Thermocouple K :-200 to +1300°C
Thermocouple J-100 to +750°C
Thermocouple T :-200 to +400°C
Courrent / voltage
- 0 to 2,5 V
- 0 to 10 V
- 0 to 4/20 mA
Supplied with current/voltage module, transport case and calibration certificate.
|
|
Hotwire VT 100
|
|
Anemometer
Functions: Hotwire velocity and airflow, temperature.
- Measuring range
- Air velocity : 0,15 to 30 m/s
- Air flow : 0 to 99999 m³/h
- Temperature : -20 to +80°C (inclued in probe)
Supplied with Ø 8mm hotwire, transport case and calibration certificate.
|
|
Hotwire VT 200
|
|
Anemometer
Functions: Velocity, airflow, temperature.
8, 000 measuring points
DATALOGGER software (option)
- Anemometer
- Ø 70 mm vane : from 0,3 to 35 m/s
- Ø 100 mm : from 0,25 to 35 m/s
- Ø 14 mm : from 0,8 to 25 m/s
- hotwire : from 0,15 to 30 m/s
- Temperature
- Temperature Pt100 :
- -20 to +80°C (in hotwire or vane probes)
- -50 to +250°C (according to model)
Thermocouple K :-200 to +1300°C
Thermocouple J-100 to +750°C
Thermocouple T :-200 to +400°C
Courrent / voltage
- 0 to 2,5 V
- 0 to 10 V
- 0 to 4/20 mA
Supplied with current/voltage module, transport case and calibration certificate.
|
|
Multi-probe AMI 300
|
|
Multifunction
Multi-parameters portable device : Pressure, air velocity,
airflow, hygrometry, temperature, air quality, tachometry.
Memory :up to 12 000 measurement points Dataloger software for
data recording and processing (option).
Supplied with calibration certificate and alu transport case.
- Anemometer
- Ø 70 mm vane : 0,3 to 35 m/s
- Ø 100 mm vane : 0,25 to 35 m/s
- Ø 14 mm vane : 0,8 to 25 m/s
- Hotwire : 0,15 to 30 m/s
- Thermometer
- Pt100 : -50 to 250°C
- Thermocouple K: -200 to +1300°c
- Thermocuple J : -100 to +750°C
- Thermocouple T : -200 to +400°C
- Manometer :
- 0 to ±500 Pa
- 0 à to ±2500 Pa
- 0 to ±10000 Pa
- 0 to ±500 mBar
- 0 to ±2000 mBar
- Pitot tube : 2 to 100 m/s
- Hygrometer :
- Air Quality (CO/CO2) :
- Tachymeter :
- 60 to 60 000 tr/min (optic)
- 30 to 20 000 tr/min (contact)
|
|
Multi-probe VT 200
|
|
Anemometer
Functions: Velocity, airflow, temperature.
8, 000 measuring points
DATALOGGER software (option)
- Anemometer
- Ø 70 mm vane : from 0,3 to 35 m/s
- Ø 100 mm : from 0,25 to 35 m/s
- Ø 14 mm : from 0,8 to 25 m/s
- hotwire : from 0,15 to 30 m/s
- Temperature
- Temperature Pt100 :
- -20 to +80°C (in hotwire or vane probes)
- -50 to +250°C (according to model)
Thermocouple K :-200 to +1300°C
Thermocouple J-100 to +750°C
Thermocouple T :-200 to +400°C
Courrent / voltage
- 0 to 2,5 V
- 0 to 10 V
- 0 to 4/20 mA
Supplied with current/voltage module, transport case and calibration certificate.
|
|
|